M1-TQ9200 series

Triple quadrupole LC-MS/MS system

Ultimate stability, unmatched sensitivity — the flagship LC-MS/MS platform

The M1-TQ9200 is engineered around core proprietary technologies — an ultra-high-pressure linear motor pump, lossless needle-in-flow injection, an actively preheated column oven, a highly stable electrospray ionisation source, a durable vacuum interface, efficient ion transfer lenses and a stable tandem quadrupole driver. Together they deliver exceptional stability, efficiency and robustness, and hold quantitative performance even under complex sample conditions.

A 700 °C symmetrically heated gas system, a large 0.6 mm aperture and off-axis pulsed ion detection combine for exceptional desolvation and detection efficiency. Orthogonal sampling, gold-coated molybdenum quadrupoles and an active exhaust system resist clogging, contamination and memory effects.

Ten consecutive on-column injections of reserpine give 1.052 % RSD for peak area and 0.0 % for retention time; across five thousand consecutive injections of 50 pg reserpine the RSD stays below 5 % — the question that matters for a laboratory running unattended sequences overnight.

M1-TQ9200 Series
M1-TQ9200 — ultra-high-pressure LC stack coupled to the triple quadrupole mass spectrometer
Peak area RSD
1.052 % (n = 10)
5000 injections
< 5 % RSD
Ion source gas
700 °C

System design

Eight changes to the ion path
Cutaway through the mass spectrometer

Eight changes to the ion path

+High-voltage linear field collision cell — axial acceleration minimises cross-contamination.
+Dual quadrupole transmission differential vacuum system for stable ion transmission.
+Needle micro-adjustment knob for rapid optimisation of spray position; integrated six-way valves for rapid flow-path switching.
+Off-axis pulsed ion detection, gold-coated molybdenum quadrupoles, orthogonal sampling and active preheat control with feedback loop.
Ion source
Ion source

Ion source

+A 700 °C symmetrically heated gas system with adjustable nebuliser gas pressure ionises across 0.2 µL/min to 3 mL/min.
+A 90° vertical ion introduction path, a large 0.6 mm aperture and high-purity nitrogen backflow give exceptional desolvation efficiency and contamination resistance.
+An active exhaust system prevents memory effects.
Ion transfer and collection
Ion transfer and collection

Ion transfer and collection

+Collision-induced focusing; the pre-quadrupole shares the main quadrupole's field radius for maximum transmission.
+CFD-designed stagnant-zone sampling maximises collection.
+A direct mechanical fore-vacuum pump keeps the turbomolecular pump clear of contamination and extends its service life.

Built in

Ultimate stability

+Actively preheated column oven, durable vacuum interface and stable tandem quadrupole driver hold retention time and response steady across long unattended sequences.

Unmatched sensitivity

+700 °C symmetrically heated gas system, 0.6 mm aperture and off-axis pulsed ion detection for exceptional desolvation and detection efficiency.

Unwavering reliability

+Orthogonal sampling, gold-coated molybdenum quadrupoles and an active exhaust system resist clogging, contamination and memory effects.

SmartLab CDS workstation

+Chromatography and mass spectrometry controlled from a single platform; automatic tuning and automated method optimisation for rapid MRM method development.
+Client–server architecture, plugin-based module management, project-centric data organisation, customisable reports and a complete audit trail.

Measured performance

Reserpine in MRM mode — ten injections for precision, five thousand for stability. Ten injections measure precision. Five thousand measure whether the ion source, the vacuum interface and the quadrupoles stay clean enough to keep giving the same answer.

Reserpine, MRM mode
Injections
10
5000
Peak area RSD
1.052 %
< 5 %
Retention time RSD
0.0 %
—
Ten consecutive on-column injections of reserpine
Ten consecutive on-column injections of reserpine
5000 consecutive injections of 50 pg reserpine
5000 consecutive injections of 50 pg reserpine

Powerful and intelligent software

SmartLab CDS

SmartLab CDS

Acquisition, processing and reporting in one workspace. Automatic tuning and automated method optimisation shorten MRM method development from an expertise-bound exercise to a routine one.

Specifications

Ion source
Gas system
700 °C, symmetrically heated
Flow range
0.2 µL/min to 3 mL/min
Introduction
90° vertical, 0.6 mm aperture, nitrogen backflow
Exhaust
Active, prevents memory effects
Mass analyser
Quadrupoles
Gold-coated molybdenum
Collision cell
High-voltage linear field, axial acceleration
Detection
Off-axis pulsed ion detection
Vacuum
Dual quadrupole differential system, direct mechanical fore-vacuum
LC front end
Pump
Ultra-high-pressure linear motor
Injection
Lossless needle-in-flow
Column oven
Actively preheated
Valves
Integrated six-way

Typical applications

+Forensic and safety — toxic substances in blood and urine, pharmaceutical impurities, illegally added chemicals
+Food safety — aflatoxin M group in dairy, 204 pesticide residues in tea, 76 veterinary drug residues
+Environmental — phenoxy acid herbicides in water, PAH residues, sulfonylurea herbicides in soil
+Medical research — testosterone, estradiol, vitamin D; hepcidin, parathyroid hormone, angiotensin

Documentation

M1-TQ9200 Series Product Catalogue
CAT-TQ9200-EN · 8 pp · PDF 13.7 MB · download form
Technical specification and tender documents
On request · signed specification sheets and compliance statements

Send us your method. We will specify the system.

Quotes include the instrument, installation and the service tier you choose. Send us the analytes, the matrix and the throughput you need.